null
INTRODUCTION
Wisman’s XDF series x-ray generator adopts new inverter design, which inludes IGBTs for power switching and provides new levels of reliability.Additionally, the audio noise at normal operation status by operating at a higher frequency will be eliminated by re-engineering of the XDF ‘s internal filament supply.
Wisman’s XDF series x-ray generator utilize a sine wave current source, produced by phase shifting series resonant circuits at switching frequencies greater than 20kHz to generate high voltage dc. Which can eliminates undesirable electromagnetic radiation normally associated with switching and power control regulators.Wisman’s XDF x-ray generator can realize the air cooling in a 5.25” (3U) high chassis by its high efficiency.The digital interface RS-232, RS-485 and ET make it integrate to your x-ray analysis system easily.
APPLICATION:
X-ray tube
X diffractometer
X fluorescence meter
Scientific research
OPTIOANLA FUNCTION:
AOL overload shutdown FG floating ground
CPC constant power output FGLL floating ground low leakage
LR low ripple NSS no slow start
SS(X) Custom slow start ATP over power shutdown
CPC constant power AT arc shutdown
DB 2 group output NAD without arc protection
FCV voltage fine adjustment RFR remote reset
SPECIFICATIONS
Input: AC220±10%, (three-phase AC220V optional)
Output: 1KV to 70KV and other maximum voltage output optional, 0V to the highest voltage adjustable.
Voltage control:
Local: the multi-turn potentiometer can set the output voltage between 0V and the highest voltage.
Remote : external 0 to 10V control signal can adjust the output from 0V to the highest output voltage.
Current control:
Local: the multi-turn potentiometer can set the current from 0 to the highest current.
Remote: external 0 to 10V control signal can transfer the current set from 0 to the highest current.
Filament voltage: 0-12Vac (DC filament can be customized)
Filament current: 0-5A adjustable (0-12A can be customized),
Voltage regulation:
Relative load: 0.005% (no load to rated load)
Relative input: ±0.005% (input voltage change is ±10%)
Current regulation:
Relative load: 0.01% (no load to rated load)
Relative input: ±0.005% (input voltage change ±10%).
Ripple voltage: 0.1% P-P +1Vrms.
Temperature coefficient: 100ppm, higher temperature coefficient can be customized.
Stability: less than 100ppm per hour after starting on for half an hour.
Ambient temperature: 0 to +50°C.
Storage temperature: -40℃ to +85℃.
Voltage and current indication: 4-digit digital panel meter with an accuracy of 1% under rated output conditions.
Dimensions:
4000W:1-60KV height 132mm (3U) width 483mm, length 610mm,
Weight: 40kg
Connector:
High-voltage output connector: The recessed insulating conduit and the high-voltage cable protruding in are connected by a metal connector. The high-voltage cable comes standard with 1 meter.
Input and output connector: DB50, including control and display signals.
Remote control of output voltage and current:
An external potentiometer can be used to remotely control the output voltage and current using the 10V voltage reference inside the power supply.
Remote voltage and current indication: JP1 contains 0 to 10V voltage and current indication signals, which can be connected to various digital or pointer meters
Computer remote measurement and control: optional computer remote control voltage, current, temperature
Add : Building 12 Phase 2 West Yungu,Fengxi New city,Xixian New Area,Shaanxi.
Tel : +86 15991371209 E-mail : Anna@wismanhv.com